All products

This range of products is what sets us apart, and has resulted in government awards for innovation & sustainability. Add sustainability to your monitoring well installations, and reduce your plastic waste footprint.

  • Using syringes for groundwater filtration in the field is a popular low-cost option. It can be an ideal choice if you are not using a pump, and have a manual device such as a bailer. When using a syringe 50ml at a time can be pushed through a filter. Small low-capacity filters can be used where turbidity is low. However if turbidity is high then it may be better to use a high capacity filter such as the AquaPore Biodegradable Filter Capsule. Syriges are available in luer-lock, catheter tipped, or eccentric tipped varieties.
  • This all pneumatic box will shut off the air supply to down-hole pumps when the tank, drum or IBC becomes full. This prevents overfilling of the drum and creating a spill. Ideal for LNAPL recovery projects. Comprising of a separate control box and tank sensor, the control box can be mounted separately from the drum. The tank sensor is screwed into the drum and connected to the control box by a small air hose. Being all pneumatic makes this inherently intrinsically safe.
  • An environmental monitoring well cap or plug made from post-consumer recycled plastic for sustainability. The TriCap provides:
    • Strong protection for your monitoring wells
    • Self locking option with additional stainless steel security bolt, using a special key tool or allen key
    • Hanger cable holes on bottom end of shaft
    • Fully sustainable, made from recycled plastic waste
    • Wide rubber ring provides a water tight seal
    • Also available in orange
  • The TriCap-LOG has been specifically designed for use with submersible groundwater level logging devices. Just like the TriCap-GAS, the hollow shaft intersects a horizontal side hole through the shaft near the bottom. An elbow fitting installed in the top enables the well to be vented to the atmosphere. Attach optional tubing to allow the vent port to be raised up above any surface water and prevent it from flowing into the well through the vent. A stainless spring clip is also provided for easy logger attachment. The Tricap-Log is the perfect choice for use with submersible groundwater logging devices.  It features an elbow fitting which vents the well to atmosphere, and a unique stainless spring clip for easy logger attachment. The TriCap is made from recycled plastic for sustainability and enables a groundwater monitoring well to be sealed and locked.
  • The TriCap-GAS has a quick connect gas fitting and dust cap installed on the top, enabling gas in the well to be monitored or sampled with a gas instrument or  suitable pump. The TriCapGas can also be locked in place with a padlock or by using a security screw or both for extra security. The TriCap has a partially hollow shaft that intersects a horizontal side hole near the bottom. This allows the well gas to be drawn in through the side hole and out the top. The side hole also serves to hang sampling or monitoring devices off the bottom of the cap while at the same time gas samples can be taken out through the shaft and out the gas quick connect fitting.
  • The Shelby sampler is a thin-walled soil sampling system. The system is used to sample soils that are particularly sensitive to sampling disturbance, as it has a very low wall thickness-to-sample area ratio. The sampler consists of a thin walled steel tube whose lower end is shaped to form a cutting edge. Fieldtech Solutions is now stocking U63 and U50 Shelby Tubes and drive heads. Drive Heads are available in AW, AWJ, or NWJ box threads.  
  • A Solution for Legacy Covers The universal FB180 lid is designed to fit legacy well covers from other manufacturers which are no longer in production. This includes the 'EE' FB180, and other similar covers. Sometimes lids can go missing or get broken on site over the years. Rather than breaking up the concrete to install a new cover, often involving costly traffic management, you can now simply replace the lid. Suitable bolts and an oring is also supplied with the lid. Please note it is not a replacement lid for our Nondo covers.
  • Landfill Leachate, and Remediation Pumps: - Fully Automatic, Float Actuated Pumps The Viridian range of pumps (VP Pumps) are designed specifically for pumping landfill leachate, landfill gas condensate and contaminated groundwater. As no down-well level control device is required, the VP pumps lend themselves to being part of a multi-well pumping system. This makes overall system control very simple. With minimal training, the site personnel quickly become confident with both pump and system. Available in a range of sizes and variations, and capable of discharging up to 1.1 litres of liquid per cycle. The bottom-filling versions are specifically designed for the harsh conditions of pumping landfill leachate. Available as a top loading version, for groundwater remediation applications, as well as a short version, and the 'LDD' (low drawdown) when minimum liquid head is vital. The VP2 and VP3 range has a reduced discharge capacity but it is ideal for smaller borehole sizes. As the VP pumps are driven by compressed air, a multi-well system would have an air-main connecting each pump - a far safer power source than electricity cables and less costly. VP Pumps also do not require an external form of control. Pulse Counters, for volume and flow rate measurement also available. Download Brochure
    VP Pumps Range

    VP Pumps Range

  • The Waterra 1 UP Peristaltic Sampling Pump can be powered by 110 and 220V AC, external 12VDC or its 12V internal battery.  Suction lifts up to 8.5m. 4 Battery Choices LIFE Batteries are Lithium Iron Phosphate batteries that weigh about one half the weight of the SLA (Sealed Lead Acid) batteries. LIFE batteries a have better discharge curve, maintaining higher voltages for longer. Available in 20 Ahr and 12 Ahr formats. A LIFE 12 Ahr 1 UP Pump weighs less than 8.1kg and the 20 AHr unit weighs less than 9.5kg. SLA Batteries are Sealed Lead Acid conventional batteries that are a less expensive than LIFE batteries, but weigh about twice as much. Available in 20 Ahr and 12 Ahr formats.
  • Turn your BioTubing into a groundwater pump Waterra footvalves or inertial pumps have long been a reliable and effective way to sample groundwater. They consist of a one-way checkvalve which connects to a length of HDPE BioTubing. Oscillating the tubing up and down in the well produces a flow of water. The tubing can also be connected to external pumps such as the Waterra Powerpack or PowerPump. Waterra footvalves can be a great sampling solution for narrow diameter wells. Fieldtech Solutions stock a range of the most popular sizes such as the D25, D32, and D16 footvalves. Each of these can connect to our BioTubing which allows it to function as a manual groundwater pump.  
  • The Hydrolift is a portable, 240v operated electric device that is used to automate the operation of the Waterra Pump System. This actuator is perfect for purging and sampling 50mm diameter monitoring wells up to 60m deep. In special circumstances it can lift up to 90m. This electrical Tubing Actuator is optimized to operate with the Standard Flow System up to its maximum effective depth and will operate with the High Flow System up to a depth of 45m. This Tubing Actuator is the ideal choice for the frequent user of the Waterra Pumping System with moderate to extreme pumping requirements (Low, Standard and High Flow). Using the Hydrolift will result in a big boost to your field sampling program. The Hydrolift is powered by a 3/4 horsepower (560 watts) electric motor and generates a 4 inch (10 cm) stroke at up to 140 cycles per minute. The Hydrolift weighs about 16 kg and requires an electrical power supply of at least 1000 watts. *Please note the Hydrolift requires a generator to power it. See image 2 for an animation on how the system works.
  • The Waterra PowerPack PP1 provides the mechanical actuation for pumping with inertial pumps to depths of over 60m, in a fully portable, single operator power unit. At 13 kg, the PowerPack PP1 provides outstanding pumping performance. The PP1 is powerful enough to lift water from over 60m depth using the Standard Flow System, and is so compact that it fits onto a back-pack frame. The PowerPack PP1 incorporates clamps for Waterra High Flow and Standard tubing sizes (adaptors are available for smaller tubes). A Honda GX-25 series, 1.0 horsepower, 4 stroke, gasoline motor powers this device, which can run for approximately 1 hour without refuelling.
  • The WC100GAS has a quick connect gas fitting and dust cap installed on the top, enabling gas in the well to be monitored or sampled with a gas instrument or suitable pump. The WC100Gas can also be locked in place with a padlock or by using a security screw or both for extra security. It has a large wing nut, designed to make it easier to tighten or release the plug. It comes with a ring below so you can hang/attach tubing, skimmers or sleeve samplers in the well.
  • The WC25Gas has a quick connect gas fitting and dust cap installed on the top, enabling gas in the well to be monitored or sampled with a gas instrument or suitable pump.
  • The 100mm well plug is manufactured from a recycled composite glass filled polymer that will not corrode, and is stronger than steel, pound for pound. The  center locking mechanism allows a padlock to be secured in a variety of positions, offering more flexibility in applications with limited space. Constructed of recycled composite glass-filled polymer which is stronger than steel pound for pound, the 100mm well plug is designed for years of worry-free use. The wing nut design with a recessed grip allows a padlock (not included) to be easily installed. The 100mm well plug has a tethering attachment at the base for use with a variety of instruments, features no metal parts, and can be disassembled for easy decontamination. The standard well plug and GasCap is available for 100mm wells.  

Title

Go to Top