  • The Heron Instruments barLog, barometric logger is used to automatically compensate readings stored on the dipperLog for changes in barometric pressure. The barLog, with readings every 1 hour and a memory capacity of 32,000 data points,  is recommended for long term monitoring or where more than one logger is deployed withing in a 5 km radius. The dedicated, intuitive software makes the dipperLog quick and easy to program and launch. Simply recover your data, save your findings in a tabular display and graph, view both parameters side by side in a split screen. Use the Heron Instruments’ barLog alongside your dipperLog Groundwater Data Logger for the most accurate data possible. Add a barLog to your quote for the dipperLog TOUGH, dipperLog 64, or dipperLog 32. Download Brochure 
  • The Waterra PowerPack PP1 provides the mechanical actuation for pumping with inertial pumps to depths of over 60m, in a fully portable, single operator power unit. At 13 kg, the PowerPack PP1 provides outstanding pumping performance. The PP1 is powerful enough to lift water from over 60m depth using the Standard Flow System, and is so compact that it fits onto a back-pack frame. The PowerPack PP1 incorporates clamps for Waterra High Flow and Standard tubing sizes (adaptors are available for smaller tubes). A Honda GX-25 series, 1.0 horsepower, 4 stroke, gasoline motor powers this device, which can run for approximately 1 hour without refuelling.
  • The Milwaukee Low FLow Kit is a convenient and reliable multi-parameter water quality monitoring system, designed specifically for low-flow groundwater sampling at a budget price. The Milwaukee Low Flow Kit contains everything you need for accurately monitoring water quality parameters during low-flow groundwater sampling, in a convenient and rugged carry case.
  • Mi605 is a portable, microprocessor-based, Dissolved Oxygen meter with automatic calibration and temperature compensation (ATC) specifically designed for spot sampling applications. Dissolved Oxygen measurements can be displayed in parts per million (ppm=mg/L) or in % of saturation. The temperature is indicated in Celsius from 0 to 50°C with 0.1 resolution. The meter compensates salinity and altitude automatically after manual input. Calibration is very simple and fast: just expose the polarographic Dissolved Oxygen probe MA840, supplied with the instrument, to air and press the CAL button. No need for chemical solutions! A HOLD button allows the user to freeze the reading on the LCD. The low battery indicator and the easy to replace screw on cap membranes make the Mi605 a compact instrument and ideal for all applications: aquaculture, wastewater, environmental and educational.  
  • Liquinox is a concentrated, anionic detergent for manual and ultrasonic cleaning. Free rinsing to give you reliable results without interfering residues. Extremely mild and completely soluble in hard and soft water. USDA authorized. Dilute 1:100. pH 8.5
    Used to clean: Healthcare instruments, laboratory ware, vacuum equipment, tissue culture ware, personal protective equipment, sampling apparatus, catheters, tubing, wine glasses, clean rooms, medical devices, optical parts, electronic components, pharmaceutical apparatus, cosmetics manufacturing equipment, metal castings, forgings and stampings, industrial parts, pipes, tanks and reactors. Authorized by USDA for use in federally inspected meat and poultry plants. Passes inhibitory residue test for water analysis. Used for phosphate sensitive analysis ware. FDA certified. Used to remove: Soil, grit, grime, slime, grease, oils, blood, tissue, particulates, deposits, chemical and solvents. Surfaces cleaned: Corrosion inhibited formulation recommended for glass, metal, stainless steel, porcelain, ceramic, plastic, cement and fiberglass. Can be used on soft metals such as copper, aluminum, zinc and magnesium if rinsed promptly. Used for art restoration. Corrosion testing may be advisable. Cleaning method: Soak, brush, sponge, cloth, ultrasonic, flow through clean-inplace. Will foam—not for spray or machine use. Directions: Make a fresh 1% solution (2 1/2 Tbsp. per gal., 1 1/4 oz. per gal. or 10 ml per liter) in cold, warm or hot water. If available, use warm water. Use cold water for blood stains. For difficult soils, raise water temperature and use more detergent. Clean by soak, circulate, wipe or ultrasonic method. Not for spray machines, will foam. RINSE THOROUGHLY—preferably with running water. For critical cleaning, do final or all rinsing in distilled, deionized or purified water. For food contact surfaces, rinse with potable water. Used on a wide range of glass, ceramic, plastic and metal surfaces. Corrosion testing may be advisable. Formerly known as LIQUI-NOX. Tech-notes:  Is Alconox detergent the same as Liquinox detergent ?
  • Alconox is a concentrated, anionic detergent for manual and ultrasonic cleaning. Free rinsing to give you reliable results without interfering residues. Ideal for cleaning contaminants from glassware, metals, plastics, ceramic, porcelain, rubber and fiberglass. Excellent replacement for corrosive acids and hazardous solvents. FSANZ Authorized. USDA authorized. Dilute 1:100. pH 9.5

    Used to clean: Groundwater and Soil Sampling equipment,, Healthcare instruments, laboratory ware, vacuum equipment, tissue culture ware, personal protective equipment, sampling apparatus, catheters, tubing, pipes, radioactive contaminated articles, optical parts, electronic components, pharmaceutical apparatus, cosmetics manufacturing equipment, metal castings, forgings and stampings, industrial parts, tanks and reactors. Authorized by FSANZ and USDA for inspected meat and poultry plants. Passes inhibitory residue test for water analysis. Used to remove: Soil, grit, grime, buffing compound, slime, grease, oils, blood, tissue, salts, deposits, particulates, solvents, chemicals, radioisotopes, radioactive contaminations, silicon oils, mold release agents. Surfaces cleaned: Corrosion inhibited formulation recommended for glass, metal, stainless steel, porcelain, ceramic, plastic, rubber and fiberglass. Can be used on soft metals such as copper, aluminum, zinc and magnesium if rinsed promptly. Corrosion testing may be advisable. Cleaning method: Soak, brush, sponge, cloth, ultrasonic, flow through clean-inplace. Will foam—not for spray or machine use. Directions: Make a fresh 1% solution (2 1/2 Tbsp. per gal., 1 1/4 oz. per gal. or 10 grams per liter) in cold, warm, or hot water. If available use warm water. Use cold water for blood stains. For difficult soils, raise water temperature and use more detergent. Clean by soak, circulate, wipe, or ultrasonic method. Not for spray machines, will foam. For nonabrasive scouring, make paste. Use 2% solution to soak frozen stopcocks. To remove silver tarnish, soak in 1% solution in aluminum container. RINSE THOROUGHLY—preferably with running water. For critical cleaning, do final or all rinsing in distilled, deionized, or purified water. For food contact surfaces, rinse with potable water. Used on a wide range of glass, ceramic, plastic, and metal surfaces. Corrosion testing may be advisable.
  • The Mityvac Silverline Hand Pump can be used for filtering water samples, using either vaccum or pressure to move the sample through the filter. Most commonly they are used on the vaccuum setting in conjunction with the Stericup filters.
  • The InsiteIG Portable Meter is a unique instrument that combines advanced electronics with exceptional functionality and ease of use. The meter will accept any standard portable DO, SS, pH, or ORP sensor and will automatically configure itself for the correct operation. The quick-disconnect, mil-spec connectors allow for quick sensor swaps. The meter includes a 250 point data logger that records sensor type, sensor reading, date, time, and location. The included Portalog software offers several sort options to customize the downloading and reporting of collected data. The rechargeable batteries allow for 8+ hours of use between charges.

    IPM Display

    The InsiteIG PortaCaddie is an optional organizational tool, available to purchase with each sensor, that captures the meter along with the sensor and cable. The PortaCaddie is designed to manage the cable to eliminate tangles while using the system in the field. The meter, sensor, and cable are retained securely during transport and are easily deployed at the desired test location. The rugged design was built specifically for the rigors encountered by field instrumentation. The PortaCaddie was designed to offer a level of protection to the meter, sensor, and cable.

    Compatible sensors for the IPM

    Portable DO Sensor ( PDO) The Portable Dissolved Oxygen sensor incorporates optical fluorescent technology, solid state electronics, and a unique side mount element. The InsiteIG PDO sensor is the only portable optical DO sensor that does not require expensive replacement caps. Nitric Oxide does not interfere with the InsiteIG portable sensor. PDO Sensor
    • Measuring Range: 0 to 25 ppm
    • Accuracy: 1% of the reading or .05 ppm, whichever is greater
    • Repeatability: 0.01 ppm
    • Response Time: 95% in under 60 seconds
    • Resolution: 0.01 ppm below 4.00, 0.1 ppm above 4.0
    • Drift: less than 1% per year
    • Temp. Range: 0°C to 60°C
    • 20ft sensor cable
    • sensor connector
    Portable Suspended Solids Sensor ( PSS ) The Portable Suspended Solids Sensors incorporate near infrared technology to provide increased dependability of the reading when color changes in the solids occur. Fast, accurate solids readings. There are two sensor ranges available. PSS Sensor
    • Measuring Range: 0 to 30,000 mg/l total suspended solids
    • Accuracy: +/- 5% of the reading or +/- 100 mg/l whichever is greater
    • Repeatability: +/- 1% of the reading or +/- 20 mg/l whichever is greater
    • Response Time: 95% in under 60 seconds
    • Resolution: 1 mg/l below 1000 mg/l, 10 mg/l from 1001 to 9999 mg/l, 100 mg/l above 10,000 mg/l
    • Drift: less than 1% per year
    • Temp. Range: 0°C to 60°C
    • 20ft sensor cable
    • sensor connector
    PEH51 - Portable Holder (PEH) with Model 51 pH Electrode The Portable Electrode Holder (PEH) with Model 51 replaceable pH Electrode cartridge comprise the pH sensor, which incorporates embedded electronics, custom geometry, and a field proven cartridge. The embedded electronics in the PEH Holder includes a built-in electrically isolated preamp, which results in reliable digital communications and temperature compensation circuitry. Our flat glass / double reference junction construction yields a field proven cartridge producing long-lasting reliable measurements. PEH51 Sensor
    • Measuring Range: 2 to 12 pH
    • Temp. Range: 10°C to 60°C
    • 20ft sensor cable
    • sensor connector
    PEH52 - Portable Holder (PEH) with Model 52 ORP Electrode The Portable Electrode Holder with Model 52 replaceable ORP Electrode cartridge comprise the ORP sensor, which incorporates embedded electronics, custom geometry, and a field proven cartridge. Our flat glass / double reference junction construction, yields a field proven cartridge producing long-lasting reliable measurements. The embedded electronics in the PEH Holder includes a built-in electrically isolated preamp, which results in reliable digital communications and temperature measurement circuitry. PEH52 Sensor
    • Measuring Range: +/- 2000mV
    • Temp. Range: 10°C to 60°C
    • 20ft sensor cable
    • sensor connector
  • Using syringes for groundwater filtration in the field is a popular low-cost option. It can be an ideal choice if you are not using a pump, and have a manual device such as a bailer. When using a syringe 50ml at a time can be pushed through a filter. Small low-capacity filters can be used where turbidity is low. However if turbidity is high then it may be better to use a high capacity filter such as the AquaPore Biodegradable Filter Capsule. Syriges are available in luer-lock, catheter tipped, or eccentric tipped varieties.
  • A Large Well Cover with Non-Metallic Lid The Nondo Maxi SMC well cover has a non-metallic lid, making it ideal for wells with instrumentation inside requiring data transmission through the lid, such as a telemetry system. It has an SMC (sheet moulding compound) lid, smc base ring, and a sheet metal skirt. The traditional looking 2-bolt design has a completely sealed lid with a unique one piece gasket to prevent any surface water ingress, and has been tested to exceed load bearing requirements for traffic suitability for Australian Standard AS3996 Class D. The 337mm diameter cover has an anti-slip dimpled surface on the lid, 2 bolts requiring an 8mm allen key, and a notch in the bottom of the lid to allow it to be levered off with a screwdriver. Optional add on: Nondo Safety Lifter Use the Nondo Safety Lifter tool to safely remove and reinstall the heavy lid and to avoid crushed fingers.  
  • A Solution for Legacy Covers The universal FB180 lid is designed to fit legacy well covers from other manufacturers which are no longer in production. This includes the 'EE' FB180, and other similar covers. Sometimes lids can go missing or get broken on site over the years. Rather than breaking up the concrete to install a new cover, often involving costly traffic management, you can now simply replace the lid. Suitable bolts and an oring is also supplied with the lid. Please note it is not a replacement lid for our Nondo covers.
  • Prepacked Screen for Environmental Monitoring Wells
    • Great solution for sites prone to collapsing sands
    • Ensures accurate placement of filter media across desired interval
    • No adapters required, will thread directly onto our casing
    • Available in 50mm (PN18), 1.5m lengths
    • Male / Female threaded
    • Bottom end caps available, including the universal 'FlexiPoint 50'
     

  • When direct push sampling in sands or loose soils, a core catcher is recommended to be used in the BioLiner, which will stop the soil sample from falling out when retrieving from depth. Our core catchers are 100% recycled plastic and landfill-biodegradable.
  • Used during soil vapour monitoring, 3-way and 2-way valves are an ideal addition as part of leak testing and purging.
    • 3 way valves with 2 Female luer ports and 1 male luer lock
    • 2 way valves with 1 Female luer ports and 1 male luer Lock
       
  • LNAPL Skimming Socks for 50mm Monitoring Wells The easiest way to remove small amounts of fuels from monitoring wells is with these low-cost skimming socks. Each sock holds about 500ml.